E-941SA-1K2DPSQ

1,200-lb Electromagnetic Lock, Status LED, Bond sensor, Door Position Sensor, UL Listed

The E-941Sx series of electromagnetic locks is the ideal way to secure a door against unauthorized entry. When power is applied to the electromagnetic lock, it creates an extremely strong magnetic field. The electromagnet is strongly attracted to the steel armature plate which is mounted on the secured door. Once the electromagnet is deactivated, the secured door will function normally without any residual magnetism.

  • product_icon
  • product_icon
  • product_icon
  • UL 294 Listed (Access Control)
  • Built-in bond sensor with 3A-amp dry relay output for monitoring door lock status
  • Built-in dual-color status LED shows lock status
  • Built-in door position sensor shows open/closed status (1/2” gap)
  • Armature plate holder for door position sensor
  • Dual voltage: 12/24VDC selectable
  • Anodized aluminum housing (US28)
  • No residual magnetism
  • MOV surge protection
  • Detachable faceplate
  • Adjustable mounting bracket
  • Complete mounting hardware for typical installations
  • “L” bracket (E-941S-1K2/LQ), “Z” brackets (E-941S-1K2/ZQ) available for easy mounting
  • Lifetime Limited Warranty*
*Contact SECO-LARM for details. Applies in U.S.A. & Canada only.
Endurance Level IV
Destructive attack Level 1
Line security Level 1
Standby power Level 1
Holding Force 1200-lb
Operating Voltage 12/24 VDC
Current Draw 12VDC: 500mA 24VDC: 250mA
Door Position Sensor Reed switch, 0.2A@12VDC
Operating Temperature 32°~120°F (0°~49°C)
Electromagnet Dimensions 10-1/2″x2-7/16″x1-9/16″ (267x62x40 mm)
Armature Dimensions 7-1/4″x2-7/16″x5/8″ (185x62x16 mm)
Bond Sensor SPDT relay, 3A@12VDC
UL Listed UL 294, ULC S104, UL10B, UL10C

Product Information Sheet (PI)

MANUAL

Mounting Template

Doors lock, but can easily be forced open
  • Make sure the electromagnet and armature plates are properly aligned.
  • Make sure the contact surfaces of the electromagnet and armature plates are clean and free from rust.
  • Check the power leads with a meter, and make sure 12VDC or 24VDC is present.
  • Make sure the rubber washer is installed and free from damage.
Delay in door releasing
  • The electromagnet is fitted with a metal oxide varistor to prevent interference, so do not install a second diode.
  • Ensure that the control device is connected between the power source and the positive terminal of the lock
Scroll to Top